April 20(Saturday) , 2024

Products / 产品资讯

username:
password:

Tower

Position:Home > Products > Tower > GP800 Series [1~20KVA]
GP800 Series

·Description

GP800 UPS provides single phase power protection with capacities of 1KVA-20kVA. As the new generation online smart UPS which is based on digital technologies, GP800 UPS features the topological double conversion design which eliminates interferences, compatible with generators and zero transfer time when in emergency. The perfect protection circuit improved its stabilities and reliabilities. ABM technology protects batteries effectively. Clients may check the operating status and the historical data of UPS on PC via R232. Unattended and remote control management are available by SNMP and its related software. GP800 UPS provide you best protection for computers, servers, networks equipments in telecommunication, finance, insurance, government, transportation, medical labs and so on.

·Features

■Advanced 32-bit microprocessor improved the stability and reliability;

■SPWM technology, IGBT power module and output isolation transformer greatly reduced the interferences;

■Advanced EMI technology is compliant with EN50091-2 and IEC61000-4;

■Wide input voltage range of 304V-456V to extend the battery life;

■ABM technology maximizes battery performance, life, and reliability through smart and precise charging;

■Cold start function enables you to power on the unit without any input power. It provides temporary emergency battery power when the utility power is out;
■Self-diagnosis at startup reduced risks of system failure;

■Automatic protection of over charge, over discharge, under-voltage and over load;

■LCD displays current, voltage, frequency, fault information, environment, operating condition and loads status;
■LED displays supply modes, inverter supply, bypass supply and UPS emergency;
■Alarm indicators: Battery low voltage, overload, emergency;
■Standard RS232 interface and optional SNMP card enable its communication with PC;

·Technical Specifications

Model

GP801

GP802

GP803

GP804

GP806

GP808

GP810

GP815

GP820

UPS Capacity

1KVA

2KVA

3KVA

4KVA

6KVA

8KVA

10KVA

15KVA

20KVA

Input

Voltage

220V AC±25%/160310V AC (AVR needed)

Frequency

50(60)Hz±5%

Phase

Single phase + GND

Max. Current

6A

12A

18A

24A

34A

45A

56A

82A

110A

Output

Voltage

220VAC

Voltage stability

±1%( steady state)

Frequency

50(60)Hz

Frequency Stability

±0.5%( battery powered)

Wave Form

sine wave

Power Factor

≥0.8

Distortion

≤2% linear load

Transient Response

voltage change ≤ 4% (100% loads throw or cut out)

Crest Factor

3:1(Max)

Overload

110150% for 30sec then switch to bypass, load normal after recovery

System

Control Mode

SPWM

Efficiency

>85%

Transfer Time

0ms

Battery

Type

Sealed maintenance free lead acid battery

Voltage

48VDC

192VDC

Charge Time

8hrs 90%

Interface

LCD Display Screen

display operation state of UPS, input, output voltage; input ,output frequency; battery voltage; output power (%); model of machine; load capacity; capacity; the temperature in the machine; working condition; working mode; fault state

Low Battery Light

light up when battery voltage is low

Overload Light

light up when overload

Failure Light

light up when failure

LED Status Light

instructions: electric model; battery model; inverter power supply; bypass; UPS anomaly

Software

1. power state analysis 2. normal switching system of UPS 3. Monitoring UPS 4. implementation of UPS self diagnosis 5.automatic archives

Communication Interface

the standard RS232 interface, optional SNMP card

Warning

Outage

buzzer call 1 times every 4 seconds

Electrical Anomaly

buzzer call 1 times every 4 seconds, city power mode indicator flashing

Battery will run out

buzzer call 1 times every 4 seconds, battery mode indicator flashing, low voltage light up

Overload

overload indicator light up, the buzzer sounding

UPS Anomaly

failure indicator light up, the buzzer sounding

Operational Environment

Temperature

040

Humidity

2090% non-condensing

Altitude

less than 1000m (elevation for each additional 500m, UPS output by reducing the amount of 5%)

Noise

<58dB (1 meters distance box)

Protection

Battery

low battery shutdown, power recovery automatic restart, circuit breaker protection

Overload

overload(120%-150%) 60s then switch to bypass, load normal after recovery

Temperature

UPS internal temperature >85switch to bypass

Output Short Circuit

current limiting, automatic shutdown, circuit breaker protection

UPS Anomaly

automatic switch to bypass, power by the main power

Clutter Filter

10100KHz at 40dB; 100KHz~100MHz at 70dB

Protection Degree

IP21

Standard

Safety Standard

GB4943EN62040-1

EMC

GB7260.2EN62040-2,GB/T17626.25

Produce

YD/T1095-2018

Physical Feature

Net Weight (kg)

55

58

60

63

75

96

105

120

125

Size (mm)(W*D*H)

250*580*700

250*580*700

310*590*850

410*680*1020

Products shall be subject to any changes without additional notices. The pictures are for reference only. Please adhere to the original products in case of any mistake!