·Description

CYS series single phase EPS provided by Powerstar is specifically designed for the key loads like emergency lighting. CYS provide sine wave AC power for evacuation lights under emergency situation. In normal condition, power supply is switched to mains and at the same time charge the backup batteries intelligently. When the power supply goes blackout or the voltage is 25% over the normal voltage, reverse signal will be provided by the controller, and the reverse power resource will be activated and the device will switch to reverse resource output at the same time and it will continue to provide sine wave alternating current. When the electric supply back to normal, the emergency power resource will restore the power grid supply.

Application area:

It is ideal for important sites such as fire proctection, construction, financial places, medical places, military radars, vehicle mobile phones, anti-aircraft tunnels, underground equipments, supermarkets, shopping malls, schools, squares, railway stations, parks, stadiums and convention centers.

·Features

■Centralized power supply mode, which doesn’t need any special lights;
■Provide sine wave output with stabilized voltage and frequency without noise;
■Capable to be connected and monitored by computers and can be controlled by the fire protection center;
■LCD, LED display;
■Dual-line power supply can be switched automatically;
■Single chip design ensured the accuracy

■Simple design, convenient installation, low comprehensive cost and investment;
■Over 15 years’ service life and maintenance-free batteries (rechargeable 300-500 times) save your costs;
■Automatic switch;

■Wide application. It can provide emergent lighting for personnel evacuating, fire control and disaster rescue and other emergent situations;

■Stable lighting, reliable operation and easy maintenance;
 


·Technical Specifications
Model
CYS-0.6KW
CYS-1KW
CYS-1.5KW
CYS-2KW
CYS-3KW
CYS-4KW
Power
0.6 KW
1.0 KW
1.5 KW
2.0 KW
3.0 KW
4.0 KW
Input
Voltage
Singlephase 220V±25%
Frequency
50Hz±5%
Output
Voltage
In emergency: 220V±3%
Frequency
In emergency 50Hz±0.5%
Waveform
Sine Wave
Battery
Type
Maintenance-free lead-acid batteries
Rated Voltage
DC36/90V
DC216V
Standard Voltage
48VDC
220VDC
Charge Time
<20h
Charger
Voltage
42VDC
DC110VDC
DC258VDC
Current
3A/5A
3A
Method
Mean charging, float charging switch automatically
System
Transfer Time
<0.25s (adjustable to 0ms)
Emergency Time
90min (adjustable)
Overload
120% / 150% overloads can maintain 60 minutes / 5 seconds.
Protection
Under voltage, over current, short circuit protection
Output Loop Circuit
3 (standard type, according to the design requirements, to make the output loop)
Noise
In emergency <50dB (1m away)
Environment
Humidity
0~90% ( non-condensing)
Temperature
-25℃~40℃
Elevation
≤2500m
Adapted Loads
Applicable to all kinds of the lighting loads
Physical Feature
Size(mm)
(W*D*H)
600*220*1100
730*250*1200
750*410*1200
Weight(kg)
Emergency Time (60/90min)
60/75
80/130
150/210
215/230
240/360
320/460

 

 

Model

CYS-5KW

CYS-6KW

CYS-7KW

CYS-8KW

CYS-9KW

CYS-10KW

Power

5.0 KW

6.0 KW

7.0 KW

8.0 KW

9.0 KW

10 KW

Input

Voltage

Single-phase 220V±25%

Three-phase 380V±25%/ single-phase220V±25%

Frequency

50Hz±5%

Output

Voltage

Normal: same as the electric supply voltage In emergency220V±3%

Frequency

Normal: same as the electric supply voltage In emergency50Hz±0.5%

Waveform

Sine Wave

Battery

Type

Maintenance-free lead-acid batteries

Rated Voltage

216VDC

Standard Voltage

220VDC

Charge Time

<20h

Charger

Voltage

DC258V

Current

5A

Method

Mean charging, float charging switch automatically

System

Transfer Time

<0.25sadjustable to 0ms

Emergency Time

90minadjustable

Overload

120%/150% overloads can maintain 60 minutes / 5 minutes

Protection

Under voltage, over current, short circuit protection

Output Loop Circuit

3standard type, according to the design requirements

Noise

Normal: no noise In emergency<50dB1m away

Environment

Humidity

090% (non-condensing)

Temperature

-25℃40℃

Elevation

≤2500m

Adapted Loads

Applicable to all kinds of the lighting loads

Physical Feature

Installation Method

Floor type

Size(mm)

(W*D*H)

750*410*1500

800*600*1800

800*600*2200

Weightkg

Emergency Time (60/90min)

410/590

560/750

650/900

750/1000

850/1100

960/1200

Products shall be subject to any changes without additional notices. The pictures are for reference only. Please adhere to the original products in case of any mistake!